Place of Origin: | China |
Brand Name: | GAPHO |
Model Number: | 1xN optical switch |
Minimum Order Quantity: | 50 |
---|---|
Price: | negotiate |
Packaging Details: | Carton |
Delivery Time: | 7-10 day |
Payment Terms: | T/T, D/P |
Wavelength Range: | 850±40 / 1300±40,1550 MM; 1260 ~ 1650 SM | Test Wavelength: | 850 / 1300,1550 MM 1310 / 1550 SM |
---|---|---|---|
Return Loss: | MM ≥ 30 SM ≥ 50 | Storage Temperature: | -40 ~ +85 |
Operating Temperature: | -5 ~ +70 | Switching Time: | ≤ 10(Sequence Switch Time Of Adjacent Channel) |
High Light: | 1550nm Fiber Optical Switches,1x4 Fiber Optical Switches,Ring Network Fiber Optic Switch |
1xN High Reliability Optical Switches, 1x4 1x8 1x16 1x32 1x64 ,Ring Network ·Remote Monitoring in Optical Network
1×N Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.
Features
·More Than 128 Channels
·Low Loss and High Reliability
·Parallel Interface (TTL)
·Modularized Design
·Epoxy-free on Optical Path
Applications
·Ring Network
·Remote Monitoring in Optical Network
·Testing of Fiber, Optical Component
Specifications
Parameters | Unit | GP-OSW1×N | |||
Insertion Loss | dB | 1 < N ≤ 32 | 32 < N ≤ 64 | 64 < N ≤ 128 | |
Type: 0.8 Max: 1.0 | Type: 0.8 Max: 1.2 | Type: 0.8 Max: 1.3 | |||
Wavelength Range | nm | 850±40 / 1300±40,1550 MM | 1260 ~ 1650 SM | ||
Test Wavelength | nm | 850 / 1300,1550 MM | 1310 / 1550 SM | ||
Return Loss | dB | MM ≥ 30 SM ≥ 50 | |||
Crosstalk | dB | ≥ 70 | |||
PDL | dB | ≤ 0.05 | |||
WDL | dB | ≤ 0.25 | |||
TDL | dB | ≤ 0.25 | |||
ER (PM swtich) | dB | ≥ 16 (PoIarization Maintaining switch) | |||
Repeatability | dB | ≤ ±0.05 | |||
Durability | Cycles | ≥ 10 Million | |||
Switching Time | ms | ≤ 10(Sequence switch time of adjacent channel) | |||
Optical Power | mW | ≤500 | |||
Operating Temperature | ℃ | -5 ~ +70 | |||
Storage Temperature | ℃ | -40 ~ +85 | |||
Relative Humidity | % | 5 ~ 95 | |||
Dimension | mm | 135×40×32 (N≤12) | 135×60×32(N≤18) | 135×60×38 (N≤32) | |
150×80×67 (N≤64) | 165×100×100 (N≤98) | 185×130×130 (N≤128) |
Pin Configurations
Pin No. | Signal Name | I / O | Description |
1 | D0 | Input | TTL, Channel selection bit 0 |
2 | D1 | Input | TTL, Channel selection bit 1 |
3 | D2 | Input | TTL, Channel selection bit 2 |
4 | D3 | Input | TTL, Channel selection bit 3 |
5 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
6 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
7 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
8 | GND | Input | Ground |
9 | +5VDC | Input | 5.0±5% VDC Power Supply (max 800mA) |
Pin No. | Signal Name | I / O | Description |
2 | D0 | Input | TTL, Channel selection bit 0 |
3 | D1 | Input | TTL, Channel selection bit 1 |
4 | D2 | Input | TTL, Channel selection bit 2 |
5 | D3 | Input | TTL, Channel selection bit 3 |
6 | D4 | Input | TTL, Channel selection bit 4 |
11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
1, 9 | GND | Input | Ground |
15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
10, 13 | NA |
Pin No. | Signal Name | I / O | Description |
2 | D0 | Input | TTL, Channel selection bit 0 |
3 | D1 | Input | TTL, Channel selection bit 1 |
4 | D2 | Input | TTL, Channel selection bit 2 |
5 | D3 | Input | TTL, Channel selection bit 3 |
6 | D4 | Input | TTL, Channel selection bit 4 |
10 | D5 | Input | TTL, Channel selection bit 5 |
11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
1, 9 | GND | Input | Ground |
15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
13 | NA |
Pin No. | Signal Name | I / O | Description |
2 | D0 | Input | TTL, Channel selection bit 0 |
3 | D1 | Input | TTL, Channel selection bit 1 |
4 | D2 | Input | TTL, Channel selection bit 2 |
5 | D3 | Input | TTL, Channel selection bit 3 |
6 | D4 | Input | TTL, Channel selection bit 4 |
10 | D5 | Input | TTL, Channel selection bit 5 |
13 | D6 | Input | TTL, Channel selection bit 6 |
11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
1, 9 | GND | Input | Ground |
15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
Channel Selection Table
Max Channel | Input | Active Channel | |||||||
/RESET | D6 | D5 | D4 | D3 | D2 | D1 | D0 | ||
N=16 | 0 | x | x | x | x | x | x | x | 0 reset |
1 | x | x | x | 0 | 0 | 0 | 0 | COM → 1 | |
x | x | x | 0 | 0 | 0 | 1 | COM → 2 | ||
x | x | x | 0 | 0 | 1 | 0 | COM → 3 | ||
x | x | x | … | … | … | … | … | ||
x | x | x | 1 | 1 | 1 | 1 | COM → 16 | ||
N=128 | 0 | x | x | x | x | x | x | x | 0 reset |
1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | COM → 1 | |
0 | 0 | 0 | 0 | 0 | 0 | 1 | COM → 2 | ||
0 | 0 | 0 | 0 | 0 | 1 | 0 | COM → 3 | ||
… | … | … | … | … | … | … | … | ||
1 | 1 | 1 | 1 | 1 | 1 | 1 | COM → 128 |
Optical Route
Timing Diagram
Dimension(DBx male head or female head is defined as the actual mark of the element)
Ordering Information:
General switch : GP-OSW1×N-AB-CD-EF
Polarization maintaining switch : GP-OSW1xN-PM-AB-CD-EF
N | A | B | C | D | E | F |
Channel | Fiber Type | Test Wavelength | Tube Type |
Fiber Length (Include connector) |
Connector | Dimension |
1 ~ 128 |
SM: SM, 9/125 M5: MM, 50/125 M6: MM, 62.5/125 X: Others |
85: 850nm 13: 1310nm 15: 1550nm 1315:1310/1550nm X:Others |
9: 900um 2: 2.0mm 3: 3.0mm X: Others |
05: 0.5m±5cm 10: 1.0m±5cm 15: 1.5m±5cm X: Others |
OO:None FP: FC/PC FA: FC/APC SP: SC/PC SA: SC/APC STP: ST/PC STA: ST/APC LP: LC/PC LA: LC/APC X: Others |
01: 135×40×32-DB9 02: 135×60×32-DB9 03: 135×60×32-DB15 04: 135×60×38-DB15 05: 150×80×67-DB15 06: 185×130×130-DB15 X: Others
|
Contact Person: gapho
Tel: +8618924585948
GAPHO Fiber Optic Fan Out Kit 6 Core 12 Core 0.9 Breakout Fanout Solutions
Custom 12 core 24 core optical fiber fan out kit 3mm cable diameter cable protection
Multifunctional Ribbon Cable Splitter Spider Fan Out Kit 96 Core
Network Security And Monitoring Fiber Optic Switch D2x2B Dual Bypass
RS232 16 Port Rack Mount Ethernet Switch Fiber Optic Passive Components
GaPho D2x2 Mechanical Optical Ethernet Switch , Fiber Bypass Switch
1XN Desktop Fiber Optic Switch Multifunctional Low Insertion Loss
48 Port LC Fiber Patch Panel 96 Core 2U Indoor Use Protective
GaPho High Power EDFA Optical Amplifier Highly Reliable
MPO/MTP Fiber Distribution Frame 2U 19" Patch Panel For 8 LGX Adapter Plates
1U 19 Inch FTTB ST Optical Cable Terminal Box , ST Patch Panel 24 Port